TrendView Standard 1.0.0 - Synthetic Examples Three synthetic example datasets; four data files. These are demonstration data, not an actual plant, site or customer. All examples contain 16 signals over a three-minute turbine scenario: stopped, start at 10 s, acceleration to 60 s, loading at 65-90 s, stable operation, a small disturbance at 113-127 s, recovery, and controlled unloading/shutdown from 155-180 s. No trip occurs. MicroNet LOG: Open the supplied .log file in TrendView Standard. Analogue and digital channels demonstrate 250/500/1000 ms sample rates. MicroNet loading requires the timestamp/time-zone in the filename; 2026-10-06 12.00.00 (UTC+0) is the synthetic time and naming example. Preserve this filename structure when copying the LOG. FactoryTalk DAT: Open TrendView_Example_DAT.dat (the Float/data table). Keep TrendView_Example_DAT (Tagname).dat beside it: these two files form ONE dataset. Copy them together, preferably into their own directory. The catalog supplies the signal names; samples are at 500 ms. No String table is required. DAT timestamps are synthetic clock times. CSV: Open TrendView_Example_CSV.csv. It is UTF-8, comma-delimited, with a Timestamp column and 16 numeric signal columns. Alternating 400/600 ms spacing demonstrates a non-uniform timebase. Timestamps are synthetic UTC demonstration clock times. Signal suffixes identify engineering units: RPM, MW, PCT, C, BAR, MM_S, DEG, KV and A. START_COMMAND, RUN_STATUS and TRIP_STATUS are binary (0/1). TRIP_STATUS remains 0 throughout this positive example. Select several pens and use the table and A/B cursors to explore them.